{"id":"CVE-2026-104136","published":"2026-11-05T20:17:39.137","lastModified":"2026-11-05T20:17:39.137","description":"OpenEMR is a free and open source electronic health records and medical practice management application. Prior to 8.3.0, the new_recall branch of interface/main/messages/save.php accepts a caller-supplied pid without enforcing patient-level or recall-workflow authorization. A low-privilege authenticated user who knows or enumerates a patient identifier can retrieve patient details, contact fields, HIPAA notification preferences, recent appointment information, and existing recall information. This issue is fixed in version 8.3.0.","cvssScore":null,"cvssSeverity":null,"cvssVector":null,"cwes":["CWE-284"],"vendors":[],"products":[],"references":[{"url":"https://github.com/openemr/openemr/commit/12fb549fd16ceed488c9d20281dba46f098ff107","tags":[]},{"url":"https://github.com/openemr/openemr/pull/13343","tags":[]},{"url":"https://github.com/openemr/openemr/releases/tag/v8_3_0","tags":[]},{"url":"https://github.com/openemr/openemr/security/advisories/GHSA-x6w3-3g4m-5m5v","tags":[]}],"exploitRefs":[{"url":"https://github.com/openemr/openemr/commit/12fb549fd16ceed488c9d20281dba46f098ff107","tags":[]},{"url":"https://github.com/openemr/openemr/pull/13343","tags":[]},{"url":"https://github.com/openemr/openemr/releases/tag/v8_3_0","tags":[]},{"url":"https://github.com/openemr/openemr/security/advisories/GHSA-x6w3-3g4m-5m5v","tags":[]}],"hasPoc":true,"ai":null}